The effect of metal ring and liner on dimensional precision of base-metal castings.

Document Type : original article

Authors

Assistant Professor of Prosthodontic Dept, Dental School, Mashhad University of Medical Sciences,Mashhad, Iran

Abstract

Introduction
Several procedures have been suggested for compensating the solidification shrinkage of the casting through investment expansion, among which using the metal ring or liner inside the ring may be mentioned. The purpose of this study was  to evaluate the effect of metal ring and liner on the marginal integrity of base metal crowns.
Materials & Methods
30 metal dies were made and divided into 3 groups of 10 .Metal copings were waxed up for all dies and invested using 3 methods. Group 1: with metal ring and liner; Group 2: with metal ring and without liner; Group 3: without metal ring and liner. Castings were cemented on their dies. Horizontal and vertical marginal discrepancy was measured microscopically. The results were analysed using ANOVA test.
Results
Group1 (using metal ring and liner) showed the least horizontal and vertical marginal discrepancy ( p=0.001) and group 3 showed the highest discrepancy.
Conclusion
Considering the results, it is suggested that a metal ring and liner should be used for casting base metal restorations.